MS3x A/C Jumper - Please verify
#1
MS3x A/C Jumper - Please verify
Okay - so there's the A/C Faq I've read multiple times and tried to reconstruct the broken images with the words. I *think* I've done everything right - but I'm still not getting A/C. I also *think* it's not on the megasquirt side, but I just want someone to verify this is correct -
94, MS3x, Fans wired for dual control -
1Q == 1J =-|<|-= 1L == 2S
1Q and 1J are jumperd together, 1L and 2S are jumpered together, there is a diode that connects 1Q+1J and 1L+2S together with the band pointing at 1Q+1J side.
Correct?
2S - condenser fan
1L - main fan
1J - a/c switch relay
1Q - thermoswitch / pressure switch
94, MS3x, Fans wired for dual control -
1Q == 1J =-|<|-= 1L == 2S
1Q and 1J are jumperd together, 1L and 2S are jumpered together, there is a diode that connects 1Q+1J and 1L+2S together with the band pointing at 1Q+1J side.
Correct?
2S - condenser fan
1L - main fan
1J - a/c switch relay
1Q - thermoswitch / pressure switch
#2
Boost Czar
iTrader: (62)
Join Date: May 2005
Location: Chantilly, VA
Posts: 79,493
Total Cats: 4,080
No one with a MS3 or MS3x should be following ancient write-ups designed as a band-aid solution for ancient ECUs that had not the ability to control a/c properly.
With that said, no one with an ms3x should be following any ms1 or ms2 write-ups at all.
Use the documentation on Megasquirt MSEXTRA Manual Index or Frank's MS3 writeup here: 90-97 MS3 with MS3X | My Westfield MX5 90-97 MS3 with MS3X |
your MS3x has the ability to control and handle a/c functions quite well.
Here's what you need to do for your 1994 on megasquirt 3 to control the air conditioning function:
First you got the pinout incorrect.
1Q - A/C Switch
1J - A/C Relay
2S - Condenser Fan
1L - Main Fan
Wiring:
Connect 1Q to ms3x-28. This will bring the a/c switch into the "table-switching" input.
Connect 1J to ms3x-1. This output will run from INJ-G to the a/c relay.
Connect 2S to ms3x-20. This output will from INJ-H to the a/c fan.
Connect 1L to ms3x-4. This output will run from INJ-F to the main fan.
So basically what we have done is connected the a/c switch into one of the 4 inputs, and the fans and relay on 3 separate individually controlled outputs.
now here's what you'll do in software:
To control the a/c function set it up like this --
As you can see the input is set to "tableswitch" and the output is set to the INJ output we wired to the a/c relay.
To control the a/c fan --
We set the fan control function to run the a/c fan. You'll notice it's setup to run with a/c activation and the temperature set to activate it higher than normal.
To control the main fan --
We use the generic outputs to control the main fan with a simple temperature trigger. Notice it turns on 10° before the a/c fan would otherwise.
With that said, no one with an ms3x should be following any ms1 or ms2 write-ups at all.
Use the documentation on Megasquirt MSEXTRA Manual Index or Frank's MS3 writeup here: 90-97 MS3 with MS3X | My Westfield MX5 90-97 MS3 with MS3X |
your MS3x has the ability to control and handle a/c functions quite well.
Here's what you need to do for your 1994 on megasquirt 3 to control the air conditioning function:
First you got the pinout incorrect.
1Q - A/C Switch
1J - A/C Relay
2S - Condenser Fan
1L - Main Fan
Wiring:
Connect 1Q to ms3x-28. This will bring the a/c switch into the "table-switching" input.
Connect 1J to ms3x-1. This output will run from INJ-G to the a/c relay.
Connect 2S to ms3x-20. This output will from INJ-H to the a/c fan.
Connect 1L to ms3x-4. This output will run from INJ-F to the main fan.
So basically what we have done is connected the a/c switch into one of the 4 inputs, and the fans and relay on 3 separate individually controlled outputs.
now here's what you'll do in software:
To control the a/c function set it up like this --
As you can see the input is set to "tableswitch" and the output is set to the INJ output we wired to the a/c relay.
To control the a/c fan --
We set the fan control function to run the a/c fan. You'll notice it's setup to run with a/c activation and the temperature set to activate it higher than normal.
To control the main fan --
We use the generic outputs to control the main fan with a simple temperature trigger. Notice it turns on 10° before the a/c fan would otherwise.
Thread
Thread Starter
Forum
Replies
Last Post
russian
Miata parts for sale/trade
6
10-08-2015 03:01 PM
Mikel
MEGAsquirt
4
09-28-2015 04:46 PM